PRODUCTS
🏭 Industry Application
Product Performance
🔧 Product Feature
EV Charging Stations Industry Application

Filtration for Power Equipment

Professional air filtration for EV charging devices, protecting against dust and sand ingress to ensure stable, reliable operation of charging piles and station infrastructure.

View Related Products
Cleanroom & Semiconductor Industry Application

Ultra-High Cleanliness Filtration

Ultra-high efficiency filtration for semiconductor wafer fabs and precision electronics cleanrooms, capturing nano-scale particles to meet ISO Class 1–3 standards and maximize product yield.

View Related Products
Commercial HVAC Industry Application

Central Air System Filtration

High-efficiency filtration for commercial building HVAC systems, improving indoor air quality, reducing energy consumption, and extending equipment service life.

View Related Products
Data Centers Industry Application

Precision Equipment Protection

Precision air filtration for data centers, shielding servers and critical hardware from dust contamination to keep cooling systems running efficiently and reliably.

View Related Products
Livestock & Farming Industry Application

Farming Environment Purification

Dedicated filtration systems for farms and livestock facilities — capturing dust, adsorbing ammonia, and inhibiting pathogen spread to improve animal health and overall productivity.

View Related Products
Spray Booths & Industrial Dust Industry Application

Paint Mist & Dust Purification

Designed for spray booths and grinding workshops, efficiently capturing paint mist, metal dust, and wood chips to meet emission standards while protecting finished surface quality.

View Related Products
Pre-Filter (G1–G4) Product Performance

First-Stage Large-Particle Capture

The first line of defense, capturing particles ≥5 μm such as dust, hair, and fibers to protect downstream filters and extend overall system service life.

View Related Products
Medium-Efficiency Filter (F5–F9) Product Performance

Precise PM2.5 Capture

Captures fine particles of 1–5 μm including PM2.5, pollen, and mold spores, significantly improving indoor air quality for commercial HVAC and ventilation systems.

View Related Products
HEPA High-Efficiency Filter Product Performance

Sterile-Grade Purification

≥99.97% filtration efficiency for particles ≥0.3 μm, delivering sterile-grade clean air widely used in medical, pharmaceutical, and electronics manufacturing.

View Related Products
ULPA Ultra-High Efficiency Filter Product Performance

Sub-Micron Particle Capture

≥99.9995% efficiency for particles ≥0.12 μm, meeting the extreme cleanliness demands of semiconductor fabs, aerospace, and other ultra-precision applications.

View Related Products
Related Products
High-Temperature Resistant Product Feature

Industrial-Grade Heat Tolerance

Built with specialized heat-resistant materials, operating stably up to 250°C for paint ovens, industrial dryers, and high-temperature process environments.

View Related Products
Washable & Reusable Product Feature

Cut Costs, Reduce Waste

Cleanable by water washing or air blowing, reusable multiple times to significantly reduce replacement frequency and O&M costs — an economical, eco-friendly choice.

View Related Products
Activated Carbon Product Feature

Odor & Harmful Gas Removal

Leverages activated carbon's high adsorption capacity to eliminate odors, VOCs, and formaldehyde, ideal for newly renovated spaces and industrial exhaust treatment.

View Related Products
Bag Filter Product Feature

High Dust-Holding, Long Life

Bag-style construction delivers a larger filtration area, high dust-holding capacity, and extended service life — ideal for high-dust environments with reduced replacement frequency.

View Related Products
Panel / Pleated Filter Product Feature

Compact Space-Saving Design

Compact form factor for easy installation and replacement; pleated structure maximizes filtration area within a small footprint for higher efficiency.

View Related Products
Low-Resistance Airflow Product Feature

Energy-Saving Operation

Low-resistance design minimizes pressure drop while maintaining filtration performance, reducing fan energy consumption for cost-effective, eco-friendly operation.

View Related Products
Related Products

250 Degree High Temperature Pleated Panel HEPA Filter

Paint Booth Ceiling Air Filter Media (WS-600G)

Paint Booth Ceiling Air Filter Media (WS-ZR600G)

Metal Plank Air Filter Mesh Filter

High Temperature Fiberglass Panel Filter

High Temperature Panel Filter

350 Degree High Temperature Pleated Panel HEPA Filter

Cleanrooms · Healthcare · Semiconductor Cleanrooms · Healthcare · Semiconductor
2024-03-31

Industrial Coating · VOC & Dust Control Solutions

Why industrial coating, VOC and dust control are hard on air filtration

Finish defects start with particles you cannot see

A particle above roughly 0.5 µm landing on an uncured film becomes a visible crater or speck. Supply air to the booth has to be filtered to that level, continuously.

Paint mist will clog the main filter

Overspray is sticky and high in volume. If it reaches the final stage, filter life collapses and so does booth availability.

Solvent vapour is not a particle

VOCs pass straight through a particle filter. Odour and emission control needs gas-phase media, sized for the solvent load, not a finer particle filter.

Ovens are a different problem

Above about 150 °C standard media deform and embrittle. High-temperature stages have to be specified as such.

Recommended filtration system

Treat the booth as four separate filtration positions. They are not interchangeable, and moving media from one position to another is the most common cause of premature clogging and defects.

PositionTypical classWhat it capturesRecommended product
Booth supply / ceilingF5–F8 / ISO ePM1Dust entering the spray zonePaint booth ceiling filter media
Paint mist (exhaust)G3–G4, stagedOverspray, sticky mistSpray booth filter, DPA pocket filter
Exhaust / odourActivated carbonSolvent vapour, odourActivated carbon panel or pocket filter
Oven / high temperatureF7–F9 high-tempParticles at 150–250 °CHigh-temperature panel filter

Key control points

  • 1Separate supply air from exhaust air. Supply media must be clean enough not to shed fibre into the booth; exhaust media must hold paint mist without face-loading.
  • 2Stage the paint-mist capture. A coarse first layer that is changed often is cheaper than letting a fine stage absorb the overspray.
  • 3Match media to the paint chemistry. Waterborne and solvent-borne paints load differently, and some pre-filter media lose strength when saturated.
  • 4Respect the temperature class. Standard media have a service limit; above it, specify high-temperature glass fibre or equivalent.
  • 5Keep gas-phase control as its own stage. Activated carbon needs contact time and a replacement schedule based on load, not on appearance.

Frequently Asked Questions

What filter is used in a spray booth ceiling?

Ceiling (supply) air is normally filtered with F5–F8 media selected for even airflow and low shedding. The exact grade depends on the finish class the booth must deliver.

Why does my paint booth produce dirt defects?

In most cases the supply-air filtration is too coarse, the ceiling media is overloaded, or there is a bypass around a filter frame. Check grade, seating and change interval before changing paint.

Can an activated carbon filter remove paint solvent vapour?

Yes. Activated carbon adsorbs a wide range of organic solvents, but capacity is finite and depends on the vapour concentration and contact time. It must be replaced on a load-based schedule.

What temperature can standard air filters handle?

Standard synthetic media are generally limited to about 100 °C. For drying ovens and similar processes, use high-temperature media rated for the actual operating temperature.

How can we reduce filter replacement cost?

Add or improve the pre-filtration stage, change the cheapest stage more often, and monitor pressure drop so filters are changed on condition rather than by habit.

Key Takeaways — Four positions, four different media: booth supply, paint mist, gas phase and oven. Specify each one for its own job and change it on resistance.